Client
ALSTOM PORTUGAL
Owner
SOLWAY
Location
Portugal
Scope of work
Design and Supply
Year of completion
2003
Status
Delivered
KEY STAFF
Project Director M. Rognoni
Project Manager P. Lucchi
Process Manager D. Bonicelli
Chief Designer D. Bonicelli
Quality Controller D. Quaranta
PROCESS
Water to be treated Condensate water
Total Capacity 175 t/h
Number of units 1 x 100%
Guaranteed O2 content 0,005 ppm
Process Arrangement Spray and Trays thermal deaerator
Design pressure 8 bar abs/Full Vacuum
Design temperature 250°C
Materials Shell and heads in A 516 gr 70
Notes:
Design of spray valves and trays by SWS. Trays mod. WTA.
Tower arranged vertically connected to the tank with 1 downcomer + 1 internal steam balance.
Constructed in OLMAR workshop (Italy)
Performanced complimented by ALSTOM
Download files connected with the Project
For any further information whatsoever contact: swsinfo@swsonweb.com